Welcome to the official website of Hunan Xiangneng Long Pump Maintenance Service Co., Ltd.
Technology Center
TECHNOLOGY CENTER
Circulating water pump impeller repair and energy-saving technology
Release time:
2021-10-19 16:02
Wang Xinghai
(Sinopec Great Wall Energy Chemical (Ningxia) Co., Ltd., Yinchuan, Ningxia 750411)
Abstract: In view of the cavitation, wear, corrosion, and perforation of the impeller blades of the circulating water pump, polymer repair materials are used to repair the cavitation damage area of the water pump impeller, and the entire inner surface of the pump cavity and the front and rear reducers are energy-saving. Effective coating increases the service life of the impeller and has achieved significant energy-saving effects.
1 Overview
Sinopec Great Wall Energy Chemical (Ningxia) Co., Ltd. Acetic Acid Operation Department Circulating Water Field, with a circulating water volume of 60,000 m3/h, responsible for providing heat exchange water to the Acetic Acid Operation Department, PVA Operation Department, and Acetylene Operation Department. There are 9 pump rooms in total. Two double-suction circulating water pumps, produced by Shanghai Dongfang Pump Industry Group Co., Ltd., the specific models and quantities are as follows:
|
name |
Tag |
Specification |
main material |
amount |
|
Circulating pump |
PP450B-10ADE |
DFss955B-3/80 |
Nodular cast iron/cast steel |
4 |
|
Circulating pump |
PP450B210AD |
DFss855B-5/80 |
Nodular cast iron/cast steel |
P |
Since the circulating water pump was put into production in 2013, due to the complex working conditions, the internal cavitation and corrosion of the pump body are serious, and the impeller is easy to be perforated by cavitation (see Figure 1). The service period is short, the maintenance cost is high, and the equipment operation is unsafe We believe that this situation is caused by the fact that the blade shape of the pump impeller does not meet the requirements of the on-site water flow curve, resulting in concentrated cavitation at the water inlet (negative pressure zone), fatigue damage to the metal on the water inlet side of the impeller, and perforation.

Figure 1 Impeller cavitation is serious
In view of the problems existing in the impeller of the circulating water pump, after discussion by the professional group, the solutions to be selected are shown in Table 1.
In summary, since the liquid level of the suction tank has reached the highest level, there are no technological measures to improve the suction performance. In order to ensure the long-term efficient operation of the equipment, reduce maintenance costs (replace the impeller regularly), and obtain corresponding economic benefits, after research and comparison, we The polymer repair and energy-saving coating products and technology of British DEP company are selected, and the circulating water pumps P450B-1B and P450B-2C are repaired and energy-saving technological transformation, which can achieve the purpose of extending the life cycle, repairing the old and reducing waste, saving energy and reducing consumption. .
Table 1
| plan 1 | Scenario 2 | Scheme 3 | |
| Program content |
Purchase a new impeller for replacement, and The impeller surface is coated with DEP anti-wear coating |
Repair the cavitation defects of the impeller, and the whole impeller is coated with DEP anti-wear coating. |
To repair the cavitation defects of the impeller, the entire impeller and pump cavity are coated with DEP synergistic coating. |
| advantage |
Relatively safe. |
The technology is mature, no stress is generated, the impeller can be repaired according to the on-site situation, and the wear-resistant and anti-corrosion treatment can be carried out. |
The energy saving effect is good, and the pump efficiency can be improved by 3%. A single pump can save 160,908 yuan in electricity costs within one year, and all the investment in repair and energy saving can be recovered. Calculated on the basis of at least 4 years of use, the total electricity cost can be saved: 643632 yuan. |
| shortcoming |
The impeller purchase cycle is long, the replacement workload is large, and the construction period is long. The bearing and shaft sleeve may be damaged when replacing the impeller. |
Construction requirements are high, sandblasting is required, Spraying requires protection on site. |
The cost is high, the construction requirements are high, Sandblasting and spraying are required, and |
| Cost estimate |
Impeller 49000 yuan / pump
|
RMB 17536/pump |
117428 yuan/pump (The whole pump cavity is coated with a synergistic coating, with a large area) |
1 Practical application
1.1 The main construction technology of impeller repair and energy-saving transformation
1.1.1 Surface treatment
Sandblasting: use 14 mesh emery to sandblast all areas that need to be repaired and anticorrosive
Treatment, completely remove the surface rust layer, expose the metallic luster, and make the surface roughness up to 75
Micrometers.
Cleaning: until the surface of the pump body to be repaired is completely free of impurities, and the parasites on the substrate are fully removed.
Surface cleaning: Use acetone to clean all the surfaces after sandblasting and the 100mm area around them to thoroughly remove the floating dust on the surface of the area.
Important parts such as bearing holes must be completely wrapped with cloth to prevent damage during sandblasting.
1.1.2 The impeller uses DEP201 to repair the impeller
Use DEP201 polymer products to repair the cavitation damage area of the pump impeller, repair and optimize the shape of the impeller, so that it can meet the hydraulic characteristics of the site and reduce the occurrence of cavitation.
Fix the reinforced mesh by welding or screws, prepare the corresponding metal mesh according to the size of the perforation, and fix the metal mesh on the perforation position of the impeller by welding or punching and tapping (see Figure 2).

Figure 2 Impeller modification
After fully mixing DEP 201, use DEP special tools to repair and fill the surface of the substrate, and apply pressure to ensure that the DEP material and the metal substrate are completely bonded. At the watershed, use the DEP reinforcement belt to increase the wear resistance of the DEP material. Repair layer by layer,
With the pre-made abrasive tools, repair to the ideal shape, and leave a certain machining allowance.
After the repair material is cured, use angle grinders, straight grinders and other tools to perform repairs. The shape of the part on the water inlet side of the impeller that is susceptible to cavitation is restored to the shape of the impeller with the lightest cavitation in the entire impeller. If it is found that the repair layer does not reach the expected shape, it must be repaired, cured, and repaired again.
1.1.1 Impeller coated with anti-cavitation coating DEP 202
After DEP 201 is repaired to the ideal profile and initially cured, DEP 202 is prepared in proportion. Apply the fully mixed DEP 202 evenly on the repaired surface with a brush. After the tentacles are dry, apply two layers. For the embedding groove position, make sure that the DEP material is sufficient.
Coating thickness: The coating thickness of DEP 202 is guaranteed to be 0.25mm-0.4mm.
1.1.2 The pump cavity is coated with energy-saving and efficiency-enhancing coating DEP 203
After finishing the surface treatment, first use DEP201 to repair the casting defect pits of the water pump to ensure the smooth flow surface of the water pump. After initial curing (within 2 hours), the
Mix DEP 203 thoroughly and apply it evenly on the repaired surface with a short-bristled brush. After the first layer of DEP 203 material is initially cured (the tentacles are not sticky), a second layer of DEP 203 material can be applied. After curing, check the continuity of the coating by visual inspection or missing coating/pore detection equipment. Where there are pores or missing coating, the surrounding area must be roughened with a coarse emery cloth and cleaned with acetone cleaning agent and then coated with DEP 203 material again. After finishing the work, immediately tear off the fiber tape.
Curing: Considering that the current ambient temperature is not high, heating and curing must be used. After curing for 24 hours at room temperature, the DEP material after the repair coating is heated and cured (80 degrees Celsius), and it can be put into use after 24 hours.
1.1 Implementation status of transformation
1.1.1 The construction situation of the reconstruction site
In January 2015, the P450B-1B and P450B-2C impeller repair and energy-saving transformation were completed. The effect of the repair and transformation is shown in Figure 3 and Figure 4.

Figure 3 Impeller repair and energy saving effect diagram

Figure 4 Pump cavity repair and energy saving effect diagram
1.1.1 Operation after transformation
After the transformation, the P450B-2C was put into operation normally, because the P450B-1B
The motor was returned to the factory for repair and did not run. Now select P450B-2C for energy-saving effect analysis. Data collection and comprehensive calculation before and after energy-saving renovation:
The operating parameters of two periods (30 days) before and after the transformation are selected for comparison, and comprehensive calculation is performed. The results are shown in Table 1:
Table 1 Comprehensive table of energy saving test and calculation
|
Item day |
Recommended |
unit |
Calculation formula |
Calculation results |
|
Data collection |
|
|
|
|
|
September 02, 2014 00:00 |
Qa1 |
kwh |
302 Substation Collection |
5295500 |
|
October 02, 2014 00:00 |
Qa2 |
kwh |
302 Substation Collection |
6475200 |
|
March 01, 2015 00:00 |
Qb1 |
kwh |
302 Substation Collection |
8605700 |
|
March 31, 2015 00:00 |
Qb2 |
kwh |
302 Substation Collection |
9670600 |
|
CWsb circulating water main pipe cumulative flow 2014-09-02 |
Va1 |
Km3 |
Acetic acid control room collection |
22704 |
|
October 02, 2014 00:00 |
Va2 |
Km3 |
Acetic acid control room collection |
33548 |
|
March 01, 2015 00:00 |
Vb1 |
Km3 |
Acetic acid control room collection |
90107 |
|
|
Vb2 |
Km3 |
Acetic acid control room collection |
105245 |
|
Cumulative circulating water flow of single pump |
will |
Km3 |
(Va2-Va1)/2 |
5422 |
|
Cumulative power consumption of single pump |
Qa |
kwh |
Qa2-Qa1 |
1179700 |
|
Specific energy consumption (1 Km3 circulating water power consumption) |
A1 |
kwh / Km3 |
Qa / Va |
217.58 |
|
P450B-2C unit energy consumption after transformation |
|
|
|
|
|
Cumulative flow of single pump |
Etc |
Km3 |
(Vb2-Vb1)/3 |
5046 |
|
Cumulative power consumption of single pump |
Qb |
kwh |
Qb2-Qb1 |
1064900 |
|
Specific energy consumption (1 Km3 circulating water power consumption) |
A2 |
kwh / Km3 |
Qb/Vb |
211.03 |
|
Energy saving rate |
|
|
(A1-A2)/A1*100 |
3.01 |
(Note: Since there is no flow meter at the outlet of a single pump, it is averaged to a single pump according to the total flow of the main pipe.)
Conclusion: After energy-saving transformation, the unit energy consumption of the circulating water pump P450B-2C in the acetic acid operation department in March 2015 (after the transformation) was 3.01% lower than that in September 2014 (before the transformation), and the energy-saving transformation achieved the expected effect.
1.1.1 Economic benefits after transformation
2015.
[3] Circulating water pump equipment information, Shanghai Dongfang Pump Industry Group Co., Ltd., 2012.
About the author: Wang Xinghai (1977-), male, from Qiyang, Hunan, graduated from Changsha University of Science and Technology in 2009 with a major in thermal energy and power engineering. Sinopec Great Wall Energy and Chemical Industry
After the transformation, a single pump increases the operating efficiency by 3.01%, and the motor power is 1600Kw. (Ningxia) Co., Ltd. is engaged in equipment management work as an engineer.
According to the company's internal related transaction price, electricity is calculated at 0.388 yuan/kwh, and it runs every year
8400 hours, saving electricity bills annually: 1600kW/h×3.01%×8400×0.388 yuan =
156963 yuan, under normal operating conditions, all investment costs can be recovered within one year.
Concluding remarks
By applying an anti-wear coating to the impeller of the circulating water pump, cavitation is delayed and the service life is prolonged; by applying a synergistic coating to the flow channel of the circulating water pump, energy consumption is saved and the operating efficiency of the water pump is improved. It has certain guiding significance for improving the cycle of circulating water pumps and reducing the energy consumption of circulating water as a whole.
references
[1] Petrochemical equipment maintenance and repair regulations. China Petrochemical Corporation [M]. Beijing: China Petrochemical Press, 2004.
[2] Circulating water pump repair and energy saving plan. Nanjing Bezona Engineering Technology Co., Ltd.,
Previous Page