Welcome to the official website of Hunan Xiangneng Long Pump Maintenance Service Co., Ltd.
MAINTENANCE AREA
MAINTENANCE AREA
Clear water vertical long shaft pump
Release time:
2021-10-19 15:14
Clear water vertical long shaft pump
● Product overview of clean water vertical long shaft pump
LC type clear water vertical long shaft pump is an advanced and mature series of products developed by absorbing domestic and foreign advanced experience in the design and manufacturing of vertical long shaft pumps to meet the needs of the domestic market. This product can be used to transport clean water, rainwater, iron oxide water, sewage, corrosive industrial wastewater, sea water and other liquids below 55°C; it can transport liquids up to 90°C after being specially designed. It is widely used in water supply companies, sewage treatment plants, power plants, steel plants, mines and other industrial and mining enterprises, as well as municipal water supply and drainage, farmland irrigation, flood control and drainage projects.
●Clear water vertical long shaft pump model meaning
200LC-23A×2-L H
200—The outlet diameter of the water pump is φ200mm;
LC—Vertical long shaft pump;
23—When the impeller is not cut, the single-stage design point head of the pump is 23m (total pump head=single-stage head×number of impeller stages);
A-cutting code of the outer diameter of the impeller;
×2—The number of impeller stages is 2 (omitted when the number of stages is 1);
L—the depth of the liquid (L≤40m, the unit is m);
H—Water pump with protective tube (omit without protective tube).
Note: The model format of 100 caliber and 150 caliber is 100LC50-20A×2-L, 150LC140-15A×2-L, where 50 and 140 represent the design point flow of the pump. The model format of the vertical long-shaft pump from 200 caliber to 1000 caliber does not include flow parameters.
●Performance range of clean water vertical long shaft pump
Flow rate: 50~8400m3/h;
Head: 15~150m.
●Structural characteristics and working principle of clear water vertical long shaft pump:
The suction inlet of the LC type energy-saving shaft pump is vertically downward, and the outlet is horizontal. It does not need to be vacuumed to start. It is installed on a single foundation. The water pump and the motor are directly connected. The foundation area is small. Features include:
1. The hydraulic design software is optimized and designed with superior performance, and fully considers the anti-abrasion performance of the impeller and guide vane body, so that the life of the impeller, guide vane body and other parts is greatly improved; the product runs smoothly, is safe and reliable, and is highly efficient and energy-saving.
2. The inlet of the LC type energy-saving vertical long axis pump is equipped with a filter screen, and the size of the opening is appropriate, which can effectively prevent large particles from entering the pump and damage the pump, while minimizing import losses and improving the efficiency of the pump.
3. The impeller of the LC type energy-saving vertical long-axis pump adopts a balance hole to balance the axial force. The front and rear cover plates of the impeller are equipped with replaceable sealing rings to protect the impeller and the guide vane body.
4. The rotor parts of LC type energy-saving vertical long shaft pump include impeller, impeller shaft, intermediate shaft, upper shaft, coupling, adjusting nut and other parts.
5. LC type energy-saving vertical long shaft pump intermediate shaft, pumping pipe and protective pipe are multi-section, and the shaft is connected by threaded coupling or sleeve coupling; the number of pumping pipes can be increased or decreased according to user needs to adapt to different liquids. Down depth. The impeller and guide vane body can be single-stage or multi-stage to meet different head requirements.
6. The length of a single shaft is reasonable and the rigidity is sufficient.
7. LC type energy-saving vertical long shaft pump water-lifting pipe adopts flange connection, and there is a guide bearing body between the two adjacent water-lifting pipes. Both the guide bearing body and the guide vane body are equipped with guide bearings, and the guide bearings are made of polytetrafluoroethylene or Cylon or nitrile rubber. The protective tube is used to protect the shaft and the guide bearing. When transporting clean water, the protective tube can be eliminated. The guide bearing does not need to be externally cooled and lubricated; when transporting sewage, the protective tube must be installed and the guide bearing must be externally cooled and lubricated (water pump with self-closing seal After the water pump stops, the self-closing sealing system can prevent sewage from entering the guide bearing).
8. The residual axial force of the LC type energy-saving vertical long shaft pump and the weight of the rotor components can be borne by the thrust bearing in the motor support or the motor with thrust bearing. Thrust bearings are lubricated with grease (also known as dry oil lubrication) or lubricating oil (also known as thin oil lubrication).
9. The shaft seal of the LC type energy-saving vertical long shaft pump is a packing seal, and the shaft seal and guide bearing are equipped with replaceable shaft sleeves to protect the shaft. The axial position of the impeller is adjusted by the upper end of the thrust bearing component or the adjustment nut in the pump coupling, which is very convenient.
10. The LC type energy-saving vertical long shaft pump with outlet diameters of φ100 and φ150 is only used to transport clean water at room temperature, without a protective tube, and the guide bearing does not need to be externally lubricated with lubricating water; if the user needs φ100 and φ150 calibers For vertical long shaft pumps with protective tubes, our company can provide additional technical solutions.
● LC type clear water vertical long shaft pump selection instructions:
1. Refer to the performance parameter table for the performance of the LC type vertical long shaft pump. The parameters listed in the table are the test performance of the clean water at room temperature under one atmospheric pressure without the pumping pipe and filter; when calculating the device head, the loss of the pumping pipe and filter Estimated at 1m loss per 5m.
2. The motor system is configured according to γ≤1100kg/M3. YLS is a 6kV motor, which can be equipped with a 10kV motor as required.
3. When ordering, please indicate the pump model, performance parameters, liquid type (see "Material Table of Main Parts"), the material of the main parts, the depth L of the liquid, whether it is equipped with a protective tube, etc.; when transporting sewage, sewage is also required The maximum size of the particles and the specific gravity of the sewage.
4. It must be noted when the temperature of the conveyed liquid is greater than 55°C.
●Clear water vertical long shaft pump parts material table:
|
|
Shimizu | Sewage | seawater | |||
| Ⅰ | Ⅱ | Ⅲ | Ⅳ | |||
| Bell mouth | HT200 | HT200 or QT400-18 | HT200Ni2Cr | 321 or 316L stainless steel | ||
| impeller | HT200 | QT400-18 or cast steel or ZG1Cr13Ni1 | ZG1Cr18Ni9Ti | ZCuZn16Si4 or 316L stainless steel | ||
| Seal ring☆ | HT200 | QT400-18 or 2Cr13 | HT200Ni2Cr | ZCuZn16Si4 or 316L stainless steel | ||
| Guide vane | HT200 | QT400-18 or cast steel | HT200Ni2Cr | ZG00Cr17Ni14Mo2 | ||
| Raising water pipe, protection pipe | Q235-A | Q235-A | 1Cr18Ni9Ti | 00Cr17Ni14Mo2 | ||
| axis | 45 or 2Cr13 | 45 or 2Cr13 | 1Cr18Ni9Ti | 00Cr17Ni14Mo2 | ||
| Bushing☆ | 2Cr13 | 2Cr13 | 1Cr17Ni2 | 1Cr17Ni2 | ||
| Guide bearing☆ | PTFE/Sailong/NBR | |||||
| Guide bearing body | HT200 | HT200 or QT400-18 | HT200Ni2Cr | ZG00Cr17Ni14Mo2 | ||
| Thread, sleeve coupling | 45 or 2Cr13 | 40Cr or 2Cr13 | 1Cr17Ni2 | 1Cr17Ni2 | ||
| Outlet elbow | Q235-A | Q235-A | 1Cr18Ni9Ti | 00Cr17Ni14Mo2 | ||
| Motor support | Q235-A | Q235-A | Q235-A | Q235-A | ||
Note: The material can be selected according to user requirements, and those with ☆ are vulnerable parts.
●Performance parameters of clean water vertical long shaft pump
| model | Flow Q | Series x | Total head H | Speed n | Shaft power Pa | Electric machine | Efficiency η | Pump weight | |
| Power P | model | ||||||||
| m3/h | m | r / min | kW | kW | % | kg | |||
| 100LC50 -20×x | 50 | 1 | 20 | 2950 | 3.9 | 5.5 | Y132S1-2 | 70 | 480+90N |
| 2 | 40 | 7.8 | 11 | Y160M1-2 | 510+90N | ||||
| 3 | 60 | 11.7 | 18.5 | Y160L-2 | 540+90N | ||||
| 4 | 80 | 15.6 | twenty two | Y180M-2 | 570+90N | ||||
| 5 | 100 | 19.5 | 30 | Y200L1-2 | 600+90N | ||||
| 6 | 120 | 23.4 | 37 | Y200L2-2 | 630+90N | ||||
| 7 | 140 | 27.3 | 37 | Y200L2-2 | 660+90N | ||||
| 150LC100 -18×x | 100 | 1 | 18 | 2950 | 6.8 | 11 | Y160M1-2 | 72 | 600+100N |
| 2 | 36 | 13.6 | twenty two | Y180M-2 | 630+100N | ||||
| 3 | 54 | 20.4 | 30 | Y200L1-2 | 660+100N | ||||
| 4 | 72 | 27.3 | 37 | Y200L2-2 | 690+100N | ||||
| 5 | 90 | 34.1 | 45 | Y225M-2 | 720+100N | ||||
| 6 | 108 | 40.9 | 55 | Y250M-2 | 750+100N | ||||
| 7 | 126 | 47.7 | 75 | Y280S-2 | 780+100N | ||||
| 8 | 144 | 54.5 | 75 | Y280S-2 | 810+100N | ||||
| 150LC140 -15×x | 140 | 1 | 15 | 2950 | 7.8 | 11 | Y160M1-2 | 73 | 600+100N |
| 2 | 30 | 15.7 | twenty two | Y180M-2 | 630+100N | ||||
| 3 | 45 | 23.5 | 37 | Y200L2-2 | 660+100N | ||||
| 4 | 60 | 31.4 | 45 | Y225M-2 | 690+100N | ||||
| 5 | 75 | 39.2 | 55 | Y250M-2 | 720+100N | ||||
| 6 | 90 | 47.0 | 75 | Y280S-2 | 750+100N | ||||
| 7 | 105 | 54.9 | 75 | Y280S-2 | 780+100N | ||||
| 8 | 120 | 62.7 | 90 | Y280M-2 | 810+100N | ||||
| 9 | 135 | 70.6 | 90 | Y280M-2 | 840+100N | ||||
| 150LC200 -20×x | 200 | 1 | 20 | 2950 | 14.9 | twenty two | Y180M-2 | 73 | 720+150N |
| 2 | 40 | 29.9 | 45 | Y225M-2 | 780+150N | ||||
| 3 | 60 | 44.8 | 55 | Y250M-2 | 860+150N | ||||
| 4 | 80 | 59.7 | 75 | Y280S-2 | 920+150N | ||||
| 5 | 100 | 74.7 | 90 | Y280M-2 | 980+150N | ||||
| 6 | 120 | 89.6 | 110 | Y315S-2 | 1040+150N | ||||
| 200LC-14.5 | 240 300 360 | 16.4 14.5 11.8 | 1480 | 14.5 15.6 17.4 | twenty two | Y180L-4 | 74.3 76 66.5 | 900+170N | |
| 200LC-19 | 240 300 360 | 21.3 19 15.4 | 1480 | 18.2 20.4 21.3 | 30 | Y200L-4 | 76.6 76.2 70.7 | 900+170N | |
| 200LC-23 | 240 300 360 | 25.3 23 20.2 | 1480 | 21.6 24.7 28.1 | 37 | Y225S-4 | 76.7 76.1 70.6 | 900+170N | |
| model | Flow Q | Total head H | Speed n | Shaft power Pa | Electric machine | Efficiency η | Pump weight | ||
| Power P | model | ||||||||
| m3/h | l/s | m | r / min | kW | kW | % | kg | ||
| 200LC-14.5×2 | 240 300 360 | 66.7 83.3 100 | 32.8 29 23.6 | 1480 | 29 31.2 34.8 | 45 | Y225M-4 | 74.3 76 66.5 | 1020+170N |
| 200LC-19×2 | 240 300 360 | 66.7 83.3 100 | 42.6 38 30.8 | 1480 | 36.4 40.8 42.6 | 55 | Y250M-4 | 76.6 76.2 70.7 | 1020+170N |
| 200LC-23×2 | 240 300 360 | 66.7 83.33 100 | 50.6 46 40.4 | 1480 | 43.2 49.4 56.2 | 75 | Y280S-4 | 76.7 76.1 70.6 | 1020+170N |
| 200LC-19×3 | 240 300 360 | 66.7 83.33 100 | 63.9 57 46.2 | 1480 | 54.6 61.2 63.9 | 75 | Y280S-4 | 76.6 76.2 70.7 | 1140+170N |
| 200LC-23×3 | 240 300 360 | 66.7 83.3 100 | 75.9 69 60.6 | 1480 | 64.8 74.1 84.3 | 110 | Y315S-4 | 76.7 76.1 70.6 | 1140+170N |
| 200LC-23×4 | 240 300 360 | 66.7 83.3 100 | 100.8 92 81.6 | 1480 | 86.0 98.4 111.2 | 132 | Y315M-4 | 76.7 76.1 70.6 | 1260+170N |
| 250LC-21 | 360 450 540 | 100 125 150 | 23.1 21 18.2 | 1480 | 30.4 32.6 35.4 | 45 | Y225M-4 | 74 79 75 | 1200+250N |
| 250LC-21A | 320 400 480 | 88.9 111.1 133.3 | 18.9 16.6 13.3 | 1480 | 21.7 23.5 26.2 | 37 | Y225S-4 | 76 76.5 66 | 1200+250N |
| 250LC-32 | 360 450 540 | 100 125 150 | 34.8 32 28.9 | 1480 | 44.4 50.6 56.8 | 75 | Y280S-4 | 74.7 77.5 76.8 | 1280+250N |
| 250LC-32A | 320 400 480 | 88.9 111.1 133.3 | 30.7 28 24.9 | 1480 | 34.7 39.7 44.8 | 55 | Y250M-4 | 76 77 72.7 | 1280+250N |
| 250LC-21×2 | 360 450 540 | 100 125 150 | 46.2 42 36.4 | 1480 | 60.8 65.2 70.8 | 90 | Y280M-4 | 74 79 75 | 1400+250N |
| 250LC-32×2 | 360 450 540 | 100 125 150 | 69.6 64 57.8 | 1480 | 88.8 101.2 113.6 | 160 | Y315L1-4 | 74.7 77.5 76.8 | 1500+250N |
| 250LC-32A×2 | 320 400 480 | 88.9 111.1 133.3 | 61.4 56 49.8 | 1480 | 69.4 79.4 89.6 | 110 | Y315S-4 | 76 77 72.7 | 1500+250N |
Note: N is the number of pumping pipe sections, total pump head = single-stage head × number of impeller stages.
| model | Flow Q | Total head H | Speed n | Shaft power Pa | Electric machine | Efficiency η | Pump weight | ||
| Power P | model | ||||||||
| m3/h | l/s | m | r / min | kW | kW | % | kg | ||
| 250LC-32×3 | 360 450 540 | 100 125 150 | 104.4 96 86.7 | 1480 | 133.2 151.8 170.4 | 220 | Y355M1-4 | 74.7 77.5 76.8 | 1720+250N |
| 250LC-32A×3 | 320 400 480 | 88.9 111.1 133.3 | 92.1 84 74.7 | 1480 | 104.1 119.1 134.4 | 160 | Y315L1-4 | 76 77 72.7 | 1500+250N |
| 300LC-25 | 540 660 750 | 150 183.3 208.3 | 27.5 25 21.6 | 1480 | 54.7 56.6 58.9 | 75 | Y280S-4 | 74 79.5 75 | 1340+270N |
| 300LC-25A | 490 600 680 | 136.1 166.8 188.9 | 22.8 21 17.9 | 1480 | 41.8 42.9 45.0 | 55 | Y250M-4 | 73 79 74 | 1340+270N |
| 300LC-39 | 540 660 750 | 150 183.3 208.3 | 43 39 35.6 | 1480 | 85.5 88.8 97.0 | 132 | Y315M-4 | 74 79 75 | 1480+270N |
| 300LC-39A | 490 600 680 | 136.1 166.8 188.9 | 35.6 32 29.5 | 1480 | 65.3 67.8 74.1 | 110 | Y315S-4 | 73 78 74 | 1480+270N |
| 300LC-25×2 | 540 660 750 | 150 183.3 208.3 | 55 50 43.2 | 1480 | 109.4 113.1 117.7 | 160 | Y315L1-4 | 74 79.5 75 | 1580+270N |
| 300LC-39×2 | 540 660 750 | 150 183.3 208.3 | 86 78 71.2 | 1480 | 171.0 177.6 194.0 | 250 | Y355M2-4 | 74 79 75 | 1780+270N |
| 300LC-39A×2 | 490 600 680 | 136.1 166.8 188.9 | 71.2 65 59 | 1480 | 130.6 135.5 148.3 | 200 | Y315L2-4 | 73 78 74 | 1780+270N |
| 350LC-19 | 750 900 1050 | 208.3 250 291.7 | 22.2 19 16.1 | 1480 | 58.1 58.4 60.6 | 90 | Y280M-4 | 78 81 76 | 1540+270N |
| 350LC-19A | 710 850 980 | 197.2 236.1 272.2 | 20 17 14.5 | 1480 | 49.8 50.7 51.5 | 75 | Y280S-4 | 78 80 75 | 1540+270N |
| 350LC-30 | 750 900 1050 | 208.3 250 291.7 | 33.5 30 25.5 | 1480 | 90.1 92.0 98.6 | 132 | 315M-4 | 76 80.5 74 | 1650+320N |
| 350LC-30A | 710 850 980 | 197.2 236.1 272.2 | 30.2 27 23 | 1480 | 78.2 80.5 85.7 | 110 | Y315S-4 | 75 79 73 | 1650+320N |
<<Long axis pump application field
1. Blast furnace and melting furnace cooling water system in steel, smelting, glass and other industries, converter hood cooling water system, converter, continuous casting machine cooling water system and hot rolling circulating water system, oxygen plant air pre-cooling circulating water system.
2. Process cooling water system for petroleum, coking, desulfurization, distillation, etc.; process and equipment cooling water system for rubber and chlor-alkali chemical industries.
3. Constant temperature reaction tank cooling water system in pharmaceutical, chemical and other industries.
4. Cooling circulating water system for steam turbine and related auxiliary equipment in thermal power plant.
5. The cooling water system of heat exchange equipment such as production process refrigeration unit and injection molding machine cooling in the injection molding industry.
6. Cooling water system for oxygen generator and acetylene generator.
7. Mechanical processing, metal heat treatment process cooling circulating water system, electronic industry clean workshop air conditioning water system, air compressor cooling water system.
8. Air compressor cooling water system in chemical fiber, pharmaceutical, textile, electronics and other industries.
9. Ice making and cold storage cooling water system.
10. Water intake and water delivery systems in the tap water industry.
11. Production water system for paper industry.
12. Central air-conditioning refrigeration and cooling circulating water systems for large hotels and hotels.
Previous Page
Previous Page