Welcome to the official website of Hunan Xiangneng Long Pump Maintenance Service Co., Ltd.
MAINTENANCE AREA
MAINTENANCE AREA
Vertical multi-stage drum bag condensate pump (TD type)
Release time:
2021-11-09 09:19
I. Overview:
The vertical multi-stage drum bag condensate pump is a new energy-saving series product developed by our company through introduction and research and development. It is suitable for large-scale thermal power plants, including 50, 100, 125 (145), 200, 300, 600, 1000 MW steam Various specifications for turbo-generator sets can also be used as high-lift and high-lift pumps for pumping other liquids with physical and chemical properties similar to clean water. The temperature of the liquid does not exceed 80°C.
Parameter range: flow Q 160~2000m3/h
Head H: 40~380m
(At the same time, there are corresponding performance parameters suitable for the power frequency of 60HZ)
2. Product features
1. The first-stage impeller adopts double-suction structure, which has high suction, that is, it has good
Cavitation performance.
2. It has a fully enclosed external cylinder type negative pressure sealing structure.
3. The flow-head curve of the pump changes smoothly and steadily, with high efficiency.
4. Compact structure and small space occupation.
5. The structure is reasonable, the operation reliability is high, and it is convenient for the maintenance of the unit.
3. Model description:
⑴、TDM860(Ⅰ,Ⅱ,Ⅲ)-5
TD—Cylinder bag multi-stage condensate pump
M-spiral pump body with double suction impeller in the initial stage, single suction impeller after the second stage, radial guide vane 860-design flow (m3/h)
Ⅰ—The axial seal adopts packing seal, and the motor bears the axial thrust.
Ⅱ—Axial seal adopts mechanical seal, and the pump body bears axial thrust.
Ⅲ—Axial seal adopts mechanical seal, and the motor bears axial thrust.
Those that do not specify Ⅰ, Ⅱ, and Ⅲ are basic types: the axial seal adopts packing seal, and the pump body bears the axial thrust.
5-Number of pump stages
⑵ Structure type: The condensate pump is a vertical tube bag type, and there are three structural combinations of hydraulic components:
① S type-radial guide vane with double suction impeller for the first stage, radial guide vane for the secondary single suction impeller, code name TDS;
②M type-spiral pump body with double-suction impeller in the initial stage, radial guide vane with secondary single-suction impeller, code name TDM;
③L type-spiral pump body with double suction impeller in the initial stage, and space guide vane of the secondary single suction impeller (diagonal flow), code-named TDL.
⑶. Installation type:
① The installation type of pump and motor is direct-coupled installation; the axial force generated by the pump is borne by the pump body, and can also be borne by the motor. The axial seal of the pump is a packing seal, and a mechanical seal can also be used.
②. The inlet and outlet pipes are arranged horizontally, with each other at 180°; the water inlet is below the pump installation layer, and the water outlet is above the pump installation layer. According to user and site requirements, the inlet and outlet pipes can be arranged horizontally, with each other at 0°, 90°, and 180°; the inlet and outlet are on the pump installation layer at the same time (it cannot be arranged at 0° at this time).
⑷ Rotation direction: from the motor to the pump, the pump rotates counterclockwise.
⑸. Material of main parts (commonly used):
Outer cylinder Q235-A/stainless steel
Impeller cast stainless steel
Shaft 45 steel/2Cr13
Shell QT450-10/QT500-7
When ordering, please indicate the material of the main parts (parts). If you have special requirements, please consult with the manufacturer about the technical requirements.
Four, structure introduction
⒈ The structure of the pump unit is a single foundation layer installation structure. The outer cylinder of the small flow type (ie TDS type) is equipped with a mounting plate; the medium and large flow type (ie TDM, TDL) is equipped with a large flange under the outer cylinder The mounting seat (cast iron material) is poured on the base layer for the second time. The water outlet elbow suspends the inner shell parts (including rotor parts, flow and water guide parts) and connects with the outer cylinder body, the motor is placed on the motor support, and the pump and the motor are connected by an elastic coupling.
⒉ The suction water chamber of the pump is a closed inner cavity of the outer cylinder. The suction port on the outer cylinder is located in the trench under the pump installation layer and connected with the outlet pipe of the condenser. The outlet of the pump is on the outlet elbow and is located in the installation Above the layer. According to the requirements of the user's site conditions, the suction port and the discharge port of the pump can be designed on the outlet elbow of the pump at the same time, located above the pump installation foundation layer, and the center lines are on the same level, arranged at 90° and 180° to each other. .
⒊ The components in the outer cylinder include suction bell mouth, pump body, transition plate, middle section, guide vane, outlet section, sealing ring, bearing, etc., which are connected to the inner casing of the pump through rods and outlet pipes, and are suspended in the outlet elbow. under.
⒋ The rotor part of the pump is composed of shaft end lock nut, main shaft, bearing sleeve, primary impeller, spacer sleeve, secondary impeller, stop sleeve, sleeve coupling, pump coupling and other parts.
⒌ According to the requirements of flow rate and suction conditions, the first stage impeller has two structural forms, single suction and double suction, and the secondary impeller is single suction with radial guide vanes or space guide vanes.
⒍ The bearings in the pump are all copper alloy sliding bearings, and the lubricating fluid is its own delivery fluid. If the conditions are special (supercritical unit or ultra-supercritical unit), the bearing material can be made of polymer plastic material, and its lubricating fluid is its own delivery fluid; the small pump bearing axial thrust is a thrust roller bearing + radial ball bearing structure , Thin oil lubrication (non-circulating oil), external cooling water cooling (depending on environmental conditions); large pump adopts the structure of thrust pad + guide pad (dilute oil lubrication).
⒎When the axial force generated by the pump is borne by the thrust bearing part of the pump body, the lifting height of the rotor is realized by adjusting the adjustment nut at the thrust bearing part. The pump coupling and the motor coupling adopt an elastic connection method, and the motor supports The seat supports the motor. If the axial force generated by the pump is borne by the motor, the lifting height of the rotor can be achieved by adjusting the adjustment nut at the pump coupling and the motor coupling. The pump coupling, adjusting nut, and motor coupling are rigidly connected; the motor is directly connected to the outlet elbow.
⒏The axial seal of the pump has two types of packing and mechanical seal. There is a pressure reducing device outside the shaft sealing device, and a pressure reducing sleeve is installed at the high pressure end of the lower part of the packing (mechanical seal) box. At the same time, a shaft is arranged outside. Sealing water piping system.
⒐In order to ensure the stable operation of the pump, there is a balance interface connected with the condenser on the outlet elbow.
Previous Page