Vertical Long Shaft Pump for Fire Fighting: Overview of XBD/XBC-LC Fire Long Shaft Pump:
XBD/XBC-LC fire-fighting long-axis pump is a single-suction, multi-stage guide vane water pump. This product is based on the lack of a large amount of tap water supply and a small area of The development of excellent hydraulic models and advanced structural design concepts at home and abroad has the characteristics of high efficiency, wide range of use, safe and reliable operation, and fast start-up. The water pump is used to transport clean water and seawater whose temperature is lower than 55°C.
Vertical Long Shaft Pump for Fire Fighting: XBD/XBC-LC Fire Long Shaft Pump Model Description:
XBD16/160-A-LC
XB--Vertical Long Shaft Fire Pump
D--Drive equipment mark (D is electric motor, C is diesel engine)
16--Design outlet pressure (multiple value of 0.1MPa)
160--design flow (l/s)
A--Impeller cutting mark
LC—Indicates that the pump is a vertical long shaft pump
Fire-fighting vertical long-axis pump: XBD/XBC-LC fire-fighting long-axis pump performance range:
Flow rate: 50~6000m3/h
Head: 15~100m
Special vertical long shaft pump for fire fighting: XBD/XBC-LC long shaft pump for fire fighting structure:
The suction inlet of the XBD/XBC-LC fire long shaft pump is vertically downward, and the outlet is horizontal. It can be started without vacuuming; when viewed from the motor or right-angle gearbox end, the rotor part of the water pump rotates counterclockwise. The main features are:
1. Installation method:
Generally, water pump units are installed on the same base layer.
2. Location of water outlet:
In general, the water outlet is located above the base layer, if the user needs it can also be located below the base layer.
3. The bearing method of axial thrust:
1) When the water pump is driven by an ordinary vertical motor, the weight of the water pump rotor and the axial thrust are borne by the thrust bearing installed on the upper part of the water pump.
2) When the water pump is driven by a vertical motor with thrust bearing, the weight and axial thrust of the water pump rotor are borne by the thrust bearing in the motor.
3) When the water pump is driven by a right-angle gearbox, the weight and axial thrust of the water pump rotor are borne by the thrust bearing installed in the right-angle gearbox.
4. Lubrication method of guide bearing:
Self-lubricating: If the medium delivered by the water pump is a clean liquid, the guide bearing can directly use the delivered medium for lubrication.
External pressure water lubrication: If the medium delivered by the water pump contains a small amount of impurities, clean pressure water needs to be connected from the outside for lubrication (the water pump has a self-closing sealing system. After the pump is stopped, the self-closing sealing system can prevent impurities from entering Guide bearing).
5. Lubrication of thrust bearing:
Thrust bearings are generally lubricated with thin oil (small pumps can also be lubricated with grease). A cooling jacket can be arranged outside the bearing body, and cooling water is used to cool the oil temperature.
6. Water pump and motor coupling:
Elastic coupling: If the axial thrust is borne by the water pump, the water pump and the motor are connected by an elastic coupling.
Rigid coupling: If the axial thrust is borne by the motor, the water pump and the motor are connected by a rigid coupling.
7. Equipped with power:
1) Equipped with ordinary vertical motor direct drive.
2). Equipped with a vertical motor with thrust bearing for direct drive.
3). Equipped with a diesel engine driven by a right-angle gearbox.
4) Equipped with horizontal high-speed motor driven by a right-angle gearbox with variable speed.
Vertical Long Shaft Pump for Fire Fighting: Description of XBD/XBC-LC Fire Long Shaft Pump Drive
The XBD-LC electric fire-fighting double-suction split pump unit is powered by a motor from a well-known manufacturer. At the same time, it can be equipped with low-voltage, high-voltage and explosion-proof motors of different protection levels according to the user's use environment and conditions. Its characteristics are simple operation and maintenance, low noise, and less equipment requirements.
XBC-LC diesel engine double-suction center-open pump unit is powered by various series of 10-1000KW diesel engines produced by Volvo, Cummins, Deutz and well-known domestic diesel engine manufacturers. It is assembled with the water pump through high-elastic coupling, clutch, reducer, etc. It has the characteristics of fast starting, reliable, strong emergency ability, compact structure and convenient protection. With manual, automatic, automatic switching, automatic charging, automatic protection (overspeed, low oil pressure, three start failures, high water temperature, low battery voltage and other alarms, shutdown protection, etc.), emergency lighting, remote monitoring connection and other functions. In order to ensure the normal operation of the unit in the cold climate below 5℃, the unit can be equipped with a cooling water pre-heating device.
Both types of units can provide automatic control cabinets to achieve the purpose of automatic control, remote monitoring and remote control.
Fire-fighting vertical long-axis pump: XBD/XBC-LC fire-fighting long-axis pump Main parts material:
Note: The materials can be selected according to user requirements.
<<Long axis pump application field
1. Blast furnace and melting furnace cooling water system in steel, smelting, glass and other industries, converter hood cooling water system, converter, continuous casting machine cooling water system and hot rolling circulating water system, oxygen plant air pre-cooling circulating water system.
2. Process cooling water system for petroleum, coking, desulfurization, distillation, etc.; process and equipment cooling water system for rubber and chlor-alkali chemical industries.
3. Constant temperature reaction tank cooling water system in pharmaceutical, chemical and other industries.
4. Cooling circulating water system for steam turbine and related auxiliary equipment in thermal power plant.
5. The cooling water system of heat exchange equipment such as production process refrigeration unit and injection molding machine cooling in the injection molding industry.
6. Cooling water system for oxygen generator and acetylene generator.
7. Mechanical processing, metal heat treatment process cooling circulating water system, electronic industry clean workshop air conditioning water system, air compressor cooling water system.
8. Air compressor cooling water system in chemical fiber, pharmaceutical, textile, electronics and other industries.
9. Ice making and cold storage cooling water system.
10. Water intake and water delivery systems in the tap water industry.
11. Production water system for paper industry.
12. Central air-conditioning refrigeration and cooling circulating water systems for large hotels and hotels.