TKX(S), LKX(S), LBX(S) vertical diagonal flow pumps are new varieties developed by our factory by introducing advanced technology from American IR company in the 1980s. They are suitable for circulating water pumps in large thermal power plants and nuclear power plants. use. Generally suitable for transporting clean water, rainwater, sewage and seawater below 55oC.
Parameter range: flow Q 0.3~25m3/s
Head H 5~90m
Features
1. Safe and reliable, long service life
2. High efficiency, the efficiency is 85~89%
3. Small size, small area, easy to construct water inlet channel.
4. Good cavitation performance
5. Reasonable structure, convenient assembly and disassembly, and easy maintenance.
Model Description
80LKXC-20A
80-The outlet diameter of the pump (inch, that is, 2000/25=80)
L- stands for vertical diagonal flow pump, T stands for adjustable blades;
K- means that the pump rotor can be extracted, B means that the rotor is not pumpable;
X- means that the pump kick outlet is below the base layer, and S means that the spit outlet is above the base layer;
C- pump design sequence;
20- Pump design point head;
A- means that the impeller is cut.
Structure description
1. Installation method
Single foundation: The motor and the pump are directly connected and installed on a foundation layer, and the outlet can be under the foundation layer or above the foundation layer.
Double foundation: The motor and the pump are installed on the respective foundation layer, and the discharge port is above the pump foundation layer.
2. The suction pool of the pump is a deep pit type, or it can be designed as a dry pit type according to requirements.
3. The pump rotor (consisting of impeller, guide vane body, shaft, etc.) is divided into pumpable and non pumpable.
4. The blades of the impeller are divided into non-adjustable, half-adjustable and full-adjustable.
5. The bearings of the pump are divided into rubber bearings, and the pump shaft is equipped with a protective sleeve, which is filled with clean pressure water.
6. The axial thrust of the pump is borne by the motor.
7. The pump impeller is usually one-stage, but it can also be counted as a multi-stage pump as required.

Structure type
The shafts of vertical diagonal flow pumps are installed vertically, the suction port is vertically downward, and the discharge port extends horizontally. The rotor components are available in two forms: extractable and non-extractable. The angle of the impeller blades of the T-type pump can be changed during the operation of the unit. There are two types of installation methods: pump and motor installed on two foundation layers and pump and motor directly connected on one foundation layer. The seal is sealed with packing. The suction pool of the pump has two types: wet pit and dry pit. The axial thrust of the vertical diagonal flow pump is generally borne by the motor, and the small vertical diagonal flow pump can also be borne by the pump itself. The impeller is usually one-stage, but can also be designed into multiple stages as required. The bearings of the vertical diagonal flow pump use rubber bearings and Sailon bearings. When rubber bearings are used, the pump shaft is equipped with a protective sleeve, and the inner clean pressure water is used for lubrication.