LC type vertical long shaft pump
Release time:
2021-11-03 10:22
LC type vertical long shaft pump is a new product developed by our company after years of research and at the same time absorbing the advantages of long shaft pumps produced by relevant domestic and foreign manufacturers. It is used for transporting clean water, rainwater, sewage and sea water below 80o. It can be widely used in primary water treatment plants, sewage treatment plants, metallurgical steel industry, power plants, mines, municipal engineering and farmland water conservancy projects.
Range of main performance parameters
● Pump outlet diameter DN: 100~2600mm
● Flow rate Q: 40~72000m3/h
● Head H: 5~260m
● Solid particles ≤80mg/L
● Allowable working pressure≤4Mpa
Pump model description
Example: 600LCBS-60×3, 600LCKX-60×3
600: Pump outlet diameter (mm)
LC: Vertical Long Shaft Pump
B: Indicates that the rotor is not withdrawable and withdrawable structure
K: Indicates the structure that the rotor can be withdrawn.
S: Indicates that the outlet of the pump is above and below the base layer
X: Indicates that the same port of the pump is below the base layer.
60: Pump design point head (m)
3: Number of pump stages (not indicated for level 1)
Supporting plan and adaptation occasion
We attach importance to energy saving and environmental protection, and adopt the optimal material combination for the flow-through components by analyzing the requirements of the medium and the operating environment to achieve safe, reliable, and economical operation.
|
project ltem |
Pump matching plan A Pump supporting program A |
Pump matching plan Q Pump supporting program Q |
Matching plan B Pump supporting program B |
Supporting plan S Pump supporting program S |
||
| 1 | 2 | 1 | 2 | |||
|
Inhale the bell mouth Suction bell |
Gray iron iron Grey cast iron |
Ductile iron Ductile cast iron |
Ductile iron Ductile cast iron |
Ultra low carbon stainless steel Extra low carbon stainless steel |
Nickel chromium cast iron Nickel-chromium cast iron |
Stainless steel Stainless steel |
|
impeller Impeller |
Gray cast Grey cast iron |
Cast steel Cast steel |
Stainless steel Stainless steel |
Duplex stainless steel Duplex S.S |
Tin bronze Tin bronze |
Tin bronze Tin bronze |
|
Guide vane Diffuser casing |
Cast steel Cast steel |
Cast steel Cast steel |
Stainless steel Stainless steel |
Duplex stainless steel Duplex S.S |
Nickel chromium cast iron Nickel-chromium cast iron |
Stainless steel Stainless steel |
|
Spindle Shaft |
45 # steel 45# steel |
45 # steel 45# steel |
Stainless steel Stainless steel |
2Cr13 | 2Cr13 | 2Cr13 |
|
Spit out elbow Dischage ellbow |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
Duplex stainless steel Duplex S.S |
Stainless steel Stainless steel |
Stainless steel Stainless steel |
|
Shaft sleeve Shaft sleeve |
45 # steel | 45 # steel |
Stainless steel Stainless steel |
1Cr18Ni9Ti | 1Cr18Ni9Ti | 1Cr18Ni9Ti |
|
Motor support Motor Support |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
|
Pump support plate Supponing plate |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
High quality steel Q235-A |
|
Guide bearing Guide bearing |
Sailong or wear-resistant rubber+HT200 Thordon or Abrasion resistant Rubber+HT200 |
|||||
|
Applications Servicesces |
Suitable for ordinary clean water and low strength requirements For pure water and lower strength require-ments |
Suitable for ordinary clean water and higher strength requirements For pure water and high strength applications |
Suitable for other corrosive media of PH∠6 containing a certain amount of particulate impurities; and higher strength requirements For media with more solid impurities PH∠6 chemical corrosion and for high strength applications |
The sea water pump | ||
|
Note: |
||||||
Features
1) It adopts hydraulic models and structures of well-known companies such as Ingersoll Rand, Hitachi, and Kubota Co., Ltd., and has high operating efficiency. Compared with similar domestic products, the efficiency is generally 3 to 5% higher, and the power of the supporting motor is generally reduced. Therefore, it not only reduces the user's purchase cost, but also reduces the user's use cost, and achieves the purpose of energy saving and consumption reduction.
2) Pumps whose outlet diameter is less than 1000mm have been serialized and standardized. It not only reduces the production cost, but also reduces the user's use cost; according to user files, common spare parts are reserved for production in advance, and the spare parts can be ordered by the user immediately and supplied immediately.
3) The pump is installed vertically, and the foundation area is small, saving the pump room and civil construction costs; if the outdoor motor is used, the pump room is not required for outdoor installation.
4) The weight of the rotor of the vertical pump is in the vertical direction, the radial force is small, the operation is stable, the vibration is small, the noise is low, and the service life is long.
5) If it adopts the extractable rotor structure, the maintenance is simple, the maintenance amount is small, and the maintenance time is saved.
6) The impeller is submerged in the pumping medium, there is no need to irrigate water when starting, and the cavitation performance is good.
7) The pump shaft, the intermediate pipe and the pump shaft protection sleeve are multi-section; the intermediate shaft adopts a sleeve coupling, which has high radial coaxiality, which can minimize the vibration of the unit; the number of intermediate pipes can be increased according to user needs Reduce, adapt to different submerged depths.
8) The impeller and the guide vane body can be designed into multiple stages, suitable for different head requirements.
9) The length of the drive shaft is reasonable, the rigidity is sufficient, the critical speed of the unit is more than 3 times the speed of the water pump, and the pump unit will never resonate.
10) The indirect pipe in the pump is connected by flanges, and the guide bearing is supported in the middle. The pump guide bearing adopts filled PTFE, rubber or Canadian Celon bearings; the shaft is protected by a protective tube. When transporting clean water, the protective tube can be eliminated, and the guide bearing does not need to be externally cooled and lubricated; when sewage is transported, the guide bearing needs to be externally cooled and lubricated. For places where there is no clean water on site or where the cost of clean water is high, a special structure can be added, and the medium delivered by the pump is filtered or separated by sedimentation to cool and lubricate the guide bearing. The lubricating water system can be equipped with additional control components such as flow and pressure relays. When the water supply volume before starting up is lower than the rated water supply volume, the pump cannot be started; when the water shortage and pressure are not enough due to some reasons (such as pipeline blockage) during operation , The relay will send out an alarm signal, the control room buzzer will sound, and the red light will alarm. At this time, the valve of the bypass system can be opened to ensure sufficient water supply. At the same time, faults can be repaired. This control system can realize remote control.
11) The axial force of the pump and the weight of the rotor components are borne by the thrust bearing of the motor or the thrust bearing designed by the pump itself. Thrust bearings are lubricated with thin oil and are cooled by external water; the thrust bearings can be embedded with temperature control components.
12) The shaft seal of the pump is a packing seal with a liquid collecting plate structure. The leakage water from the shaft seal flows into the pump pit or trench through the drain pipe, and the pump room is clean and tidy. Replaceable shaft sleeves are installed at the shaft seal and guide bearing to protect the shaft. The axial position of the impeller is adjusted by the adjustment nut on the upper end of the bearing component or the upper end of the pump coupling, which is very convenient.
13) The pump can be equipped with a control cabinet, which has a variety of functions such as automatic start and stop according to the liquid level, overload alarm and real-time remote monitoring, which can realize multi-pump networking and remote centralized control.
Structural features
The pump is a single, multi-stage vertical long shaft pump. The pump is installed vertically, the suction port is vertically downward, and the discharge port extends horizontally; the rotor parts are available in two types: extractable and non-extractable; the axial force of the pump can be borne by the motor, or it can be designed to be borne by the pump itself according to needs; The guide bearing of the pump is generally filled with PTFE, rubber or Sailon bearings, and other bearing materials can also be selected according to user requirements; the pump shaft is equipped with a protective sleeve, and clean pressure water is passed through it to lubricate and cool the guide bearing.



Previous Page
Next Page
Previous Page
Next Page